BENEFUSION VP1 VOLUMETRIC - INFUSION PUMP
S-A-S16-VP1
Friendliness
- Compact and lightweight design for easy carrying and
mounting
- Long runtime battery, suitable for emergency and patient
transfer
- Intuitive operation and easy to install IV sets
- High waterproof up to IP34, supports cleaning with water
Safety
- High accuracy up to ±5%, satisfying all clinical requirements
- Dynamic pressure display, Anti-bolus
- High sensitivity air bubble detection up to 50ul
Connectivity
- Ambulance support
- WiFi connection available
- Dock support
TECHNICAL SPECIFICATION
- Specification
- Dimension : 250 x 90 x 150mm
- Weight : <1.45kg
- Classification : CF, Class I
- Infusioon sets : Applicable to GB 8368-2005 disposals; diameters Φ 3.5-4.5mm, thickness 0.8-1.2mm
- Screen : 2.4'' LCD monochrome screen, 240 x 128 pixels
- Basic Parameter
- Infusion Mode : Rate mode, Drop rate mode
- Flow Rate Range : 0.1~600 ml/h
- VTBI : 0.1~9999 ml
- Accumulated volumn: 0.1~9999 ml, increment is 0.1 ml
- Preset time : 00:00:01-99:59:59( h:m:s) adjustable
- Increment : 0.1 ml/h
- Accuracy : ≤ ± 5%
- KVO Rate : 0.5 ml/h, unadjustable
- Bolus Rate : Manual Bolus: 0.2-600ml/h;
- Purge Rate : 600ml/h, unadjustable
- Occlusion : Low 150±113 mmHg (20kPa) Medium 525±113 mmHg (70kPa)
High 900±180 mmHg (120 kPa)
- Air Bubble Detection : Minimum 50ul; 5 levels selectable: 50ul, 100ul, 250ul, 500ul, 800ul;
default is 100ul;
- Functions
- Titration : Yes
- Keypad Lock : Yes
- Pause : Yes
- Anti-Bolus : Yes
- Self test System : Yes
- Alarm Volumn : 1-8 levels selectable
- Auto Lock : “ON” and “OFF”, 1-5 min selectable, step 1 min, default “OFF”
Language : 11, Chinese, English, French, Russian, Turkish, Portuguese, Polish, Bulgarian, Czech, Romanian
- Mounting Solution
- Dock : Supported
- Handle : Included
- Mounting Type : Standard: Vertical Pole; Optional: Horizontal Pole
- Alarm
- VTBI done, VTBI near done, KVO finish, air in line, door open, drop rate error,
- Standby time expired, occlusion, system error, system abnormal, battery low,
- Battery empty, reminder, AC power disconnection
- Power Supply
- AC Power : 100-240V (50/60Hz)
- Battery Type : Lithium
- Battery Operation Time : Standard: 4 hours@25ml/h; Optional: 8 hours@25ml/h
- Changing Time : < 6hours
- Safety Requirement
- IP Grade : IP34
- Temperature : 0~40ºC for operating, -40~70ºC for storage
- Humidity : 15~95% for operating, 10~95% for storage
- Air Pressure : 57~106kPa for operating, 50~106kPa for storage
- Connectivity
- Data Interface : Supported, RS 232
- Wireless : WiFi (Optional)
- Nurse Call : Supported
- DC Input : Supported
- Ambulance : Supported, meet EN 1789 Requirement
Brand: MINDRAY
Packing: 1 UNIT