PCA/PCEA PUMP - SPACE
S-A-8713030
Specification:
B.Braun Perfusor Space PCA/PCEA innovative drive technology not only ensures excellent startup and delivery properties, but also delivers safety and unique convenience when changing syringe
Feature:
- Comfortable PCA button with fixation clip and patient wristband.
- Dedicated key locks the syringe holder.
- Access code-protected settings.
- Integrated piston brake prevents free-flow during syringe change.
- Automatic rate calculation by calculating volume over time.
- Automatic calculation of delivery rate in ml/h based on the entry of drug concentration in conjunction with the desired dose rate (eg: ml/kg/min).
- Changing of infusion rate without delivery interruption
- Last memory retrieved, infusion will restart with continuation from the last infusion rate.
- Drug Library : up to 720 drug names including therapy data and information can be stored in 15 categories
- Drug specific soft and hard limits as well as default values can be specified
- KVO mode: the pump can continue the infusion with a preset Keep Vein Open after a pre-selected VTBI / time has passed.
- Standby time adjustable from 1 minutes up to 24 hours.
- Automatic detection of syringe sizes 2/3 ml, 5 ml, 10 ml, 20 ml, 30 ml, 50/60 ml, selectable by menu.
- Automatic bolus reduction triggered by occlusion alarm.
- Keypad lock on 2 safety levels (parameters and disposables lockable).
- LED Alarm indicator with clear alarm message in display.
- Drug specific acoustic alarm priorities can be specified.
- 9 selectable occlusion pressure levels (approx 0.1 - 1.2 bar).
- Stackable modules with or without special docking station allow easy transport
Technical details:
1. Delivery range
- 0.01-999.9 ml/h
- 0.01-99.99 ml/h in 0.01 ml/h increments
- 100.0 - 999.9 ml/h in 0.1 ml/h increments
2. Volume pre-selection
- 0.1-9999 ml
- 0.1 -99.99 ml in 0.01 ml increments
- 100.0 - 999.0 ml in 0.1 ml increments
- 1000 - 9999 ml in 1 ml increments
3. PCA Profile
- Monitoring timeframe: 1 - 24 hrs
- Dose volume limit for monitoring interval: 0.1 - 99999 ml
- Limit on number of doses for monitoring interval: 0.001 - 99999 dose
- Initial bolus: 0/0.1 - 200/1200 ml/h, 0 - 99999 dose (can be disabled)
- Basal rate: 0/0.1 - 200/1200 ml/h, 0/0.001 - 99999 dose (can be disabled)
- Lockout time: 1 - 240 min
- PCA bolus amount 0 - 99.99 ml, 0 - 99999 dose
- Bolus rate: 0 - 1800 ml/h
- Standards: Start up pre-settings can be defined for all parameters
- Overdosage prevention: Warning and max. limits can be defined for all parameters
- Country of origin: germany
Brand: B.BRAUN
Packing: 1 UNIT