Call Us Now! 6 012 2151684
For product enquiry or problem? Email us at info@smhealthcare.com.my

PRODUCTS

BTL CARDIOPOINT HOLTER H600 SYSTEM

Descriptions:

  • ECG lead system (number of leads):  3.7 or 12 leads
  • Number of electrodes attached to the patient: 5 or 10 electrodes
  • Max. record duration: 1 - 7 days* *12 leads 1 - 4 days 
  • Certified for use with children lighter than 10 kg: Yes
  • Certified for ST segment evaluation: Yes 
  • Patient activity monitoring: 2 axes accelerometer
  • Pacemaker detection: 100 μs / dedicated circuit with 40000 Hz detection function
  • Patient button / voice recording: Yes
  • Signal quality check: On built-in display or in BTL CardioPoint via USB
  • Automatic start of recording: 20 minutes after inserting the batteries
  • Automatic continuation of the record after replacing the batteries: Yes
  • ECG frequency response: 0.049 - 220 Hz (filters off)
  • Sampling frequency: ECG: Delta-Sigma A/D converter, 8 x 2000 Hz Pacemaker: 2 axis detection by dedicated circuit with 40000 Hz function
  • Digital resolution: 24 bits / 1.52 μV
  • Dynamic range:± 66 mV
  • Input signal range: Dynamic range: ±33 mV, polarisation: ±393 mV, consistent voltage offset: ±5 V
  • Common mode rejection ratio (CMRR): 5 lead cable: >100 dB, 10 lead cable: >94 dB
  • Noise level: < 7 μV
  • Dimensions (including patient cable connector): 102 x 62 x 24 mm
  • Operating conditions: Temperatuture: 1°C - 55°C, humidity: 10 % - 95 %
  • Battery type: 2 x AA > 1.2 V
  • Battery capacity / type: Lithium AA: cca 116 hours/Alkaline AA: cca 75 hours/ NIMH 2500 mAh: cca 51 hours
  • Ingress protection: IP22

Signal Overview: Graphical user interface

  • Fully customizable interface
  • Interactive trends
  • Preffered lead for analysis setting
  • Filter view settings
  • Selective view of channels

QRS Morphology:

Evalution tools

  • Automatic QRS classification into templates (N, B, V, S, J, artifact)
  • Advanced manual QRS labeling
  • Template merge
  • Group templates re-marking
  • ECG phragment view, 3 min interval view, Tiles view
  • QRS to template navigation
  • Manual measurement with auto snap to P, PQ, QRS, QT
  • Graphical split: Yes
  • Look for smilar beat: Yes 

Rhythm and Arrhytmias: 

Evalution tools

  • Interactive HR trend
  • Detailed data table
  • Automatic rhythm detection
  • (SR, STachy, SBrady AF, V rhythm, AIVR, VT, SVT, SVER)
  • Prematurity beat setting
  • Parametrs limit setting
  • Interactive patient activity trend: Yes
  • Relief map: Yes
  • Waterfall: Yes
  • Poincare: Yes 
  • Tachogram: Yes 

Ischeme Evalution 

  • Evalution tools: Interactive ST analysis, ST table, ST deviation trend Parameters limit setting, anual measurements.
  • ST level and slope trend per lead: Yes
  • ST relief map: Yes 

Including: 

  • Windows 11 Professional c/w i7processor or equivalent specification
  • 512GB SSD Hard Drive
  • 16GB RAM
  • 27'' inch LCD Monitor
  • LaserJet Printer
Code Item Packing Additional Info
S-R-B10-H600 BTL CARDIOPOINT HOLTER H600 SET (EN, DE, ES, RU), IEC 1 SET
S-R-B10-H600PC PC WORKSTATION WITH LASERJET PRINTER 1 UNIT
Brand: BTL
Our Brands:
www.studiolegalepalombo.com taylablaire.com siyavayaadventures.africa slot mahjong ways slot88 slot gacor slot Thailand live casino online judi bola online sabung ayam online WAHANABET casino online slot gacor mahjong sabung ayam online agen casino agen judi bola https://www.murakami-shoji.co.jp/recruit/ https://www.murakami-shoji.co.jp/about/ slot gacor casino online sv388 slot gacor judi bola sotocleaningservices.com basilika-boppard.de mamaknakliyat.com.tr slot mahjong gacor sabung ayam live casino sabung ayam online judi bola online slot88 live casino online mix parlay sbobet sv388